Dual Outlet Angle Valve with FIP Inlet and OD Connections

Dual outlet angle valve with FIP inlet and two OD outlet connections,
designed for applications requiring two outlet lines from one valve body.

The catalog lists 3/8″ FIP and 1/2″ FIP inlet options,
with multiple outlet combinations using 1/4″, 3/8″, 7/16″ and 1/2″ OD sizes.

Exact thread standard and outlet connection type should be confirmed before quotation.

This dual outlet angle valve combines one FIP inlet with
two outlet connections in a compact three-way configuration.

According to the current product catalog, the valve is available with
3/8″ FIP or 1/2″ FIP inlet sizes and several OD outlet
combinations ranging from 1/4″ OD to 1/2″ OD.

Because the catalog does not specify the exact pipe-thread standard,
outlet connection method, pressure rating or working temperature,
these details should be confirmed according to the required purchasing specification.

Key Features

01
Dual Outlet Design
02
FIP Inlet
03
Multiple OD Sizes
04
Multiple Size Combinations

Product Specifications

Parameter Catalog Information
Product Type Dual Outlet Angle Valve
Inlet Connection FIP
Listed Inlet Sizes 3/8″ FIP, 1/2″ FIP
Listed Outlet Sizes 1/4″ OD, 3/8″ OD, 7/16″ OD, 1/2″ OD
Number of Outlets Two
Exact Thread Standard To Be Confirmed
Exact Outlet Connection Type To Be Confirmed

Available Connection Combinations

The following combinations are listed in the current product catalog:

Inlet Outlet 1 Outlet 2
3/8″ FIP 3/8″ OD 1/4″ OD
1/2″ FIP 3/8″ OD 1/4″ OD
1/2″ FIP 3/8″ OD 3/8″ OD
1/2″ FIP 7/16″ OD 1/4″ OD
1/2″ FIP 7/16″ OD 7/16″ OD
1/2″ FIP 1/2″ OD 1/4″ OD
1/2″ FIP 1/2″ OD 1/2″ OD

Technical Buyer Notes

Confirm the Meaning of FIP Before Ordering

The catalog identifies the inlet as FIP, but it does not state
the exact thread standard.

For this reason, the product should not automatically be described as NPT,
BSPP or BSPT until the required thread specification has been confirmed.

Buyer Tip:
When requesting a quotation, specify the required thread standard rather than
providing only the nominal inlet size.

OD Size Does Not Confirm the Connection Method

The catalog lists the two outlet sizes using OD dimensions such as
1/4″, 3/8″, 7/16″ and 1/2″.

However, the catalog does not identify the exact outlet connection structure.
Therefore, these outlets should not automatically be described as compression
connections until the fitting structure is confirmed.

Confirm the Exact Three-Way Size Combination

A dual outlet angle valve should not be ordered using only one nominal size.
The inlet and both outlet sizes need to be specified together.

For example:

1/2″ FIP × 3/8″ OD × 1/4″ OD

This is more precise than requesting only a “1/2-inch dual outlet angle valve.”

OEM & Purchasing Requirements

SUNRICH FLOW works with specialized manufacturing partners in
Yuhuan, Zhejiang, China, coordinating product specifications,
production, quality control, OEM requirements, packaging and shipment
for international buyers.

For this product, OEM feasibility should be evaluated according to the
exact required specification rather than assumed from the catalog image alone.

When requesting an OEM quotation, it is useful to provide:

  • Required FIP inlet size
  • Required thread standard
  • First outlet OD size
  • Second outlet OD size
  • Required outlet connection structure
  • Order quantity
  • Reference drawing or physical sample if available
  • Logo, marking or packaging requirements if applicable

OEM Note:
OEM feasibility depends on the required product specification
and should be evaluated before production.

What Should Buyers Confirm Before Bulk Production?

Because the current catalog provides connection sizes but does not provide
detailed pressure, temperature or testing data, these requirements should
be agreed before bulk production.

Important purchasing checkpoints include:

  • Correct inlet and outlet size combination
  • Exact inlet thread standard
  • Outlet connection dimensions
  • Handle operation
  • Critical dimensional requirements
  • Required pressure or leakage test conditions
  • Marking and packaging requirements

Quality Note:
Testing requirements should be confirmed against the final purchasing
specification. No specific test pressure is claimed because it is not
provided in the current catalog.

Frequently Asked Questions

What inlet sizes are listed for this dual outlet angle valve?

The catalog lists 3/8″ FIP and 1/2″ FIP inlet options.

What outlet sizes are available?

The listed OD outlet sizes include 1/4″, 3/8″, 7/16″ and 1/2″,
depending on the selected connection combination.

Is the FIP inlet NPT?

The catalog only identifies the connection as FIP and does not
specify NPT, BSPP or BSPT. The exact thread standard should therefore
be confirmed before ordering.

Are the OD outlets compression connections?

The catalog provides OD sizes but does not specify the exact outlet
connection method. The connection structure should be confirmed
according to the required application or reference sample.

What pressure rating does this valve have?

A pressure rating is not stated in the current catalog information.
Required pressure and testing conditions should be confirmed before quotation.

What information should I provide for a quotation?

Provide the required inlet size, exact thread standard, both outlet sizes,
connection requirement, quantity and any reference drawing or sample available.

Need a Dual Outlet Angle Valve?

Send us your required FIP inlet size, two outlet sizes,
connection standard and quantity. We can evaluate a suitable specification.

Scroll to Top